This is samsung drive too.

Specification

Information

Here is some basic information of this SSD in the following table, such as its model name and some identifier.

ITEM INFORMATION
Vendor ID Samsung Electronics Co Ltd (0x144d)
Device ID 0xa808
Controller Vendor ID Samsung Electronics Co Ltd (0x144d)
Controller Device ID 0xa801
Model Number PM981 NVMe SED Samsung 1TB
Firmware Revision EXA72D2Q
PCIe Link Gen3 x4
L1 substates Yes
NVMe Specification Version 1.2
LBA size (byte) 512
Capacity (GB) 1024
Number of Namespaces 1
Maximum Data Transfer Size (KBytes) 2048
Write Speed (MB/s, up to) 1600
Read Speed (MB/s, up to) 3000
Host Memory Buffer Preferred Size (KBytes) 0
Host Memory Buffer Minimum Size (KBytes) 0
Write Speed (MB/s, HMB enabled, up to) 1600
Read Speed (MB/s, HMB enabled, up to) 3000
page-tag-nand 3D-TLC
page-tag-vendor Samsung
page-tag-controller Samsung
page-tag-form-factor 2280
Warrenty (year) 5

NVMe hosts and devices communicate commands and completions data in Submittion and Competion Queues. Queue is the most essential data structure defined by NVMe specification.

INFORMATION
Admin Queue Size 128
Maximum Queue Entries Supported 16384
Number of Queues 32
Arbitration Mechanism Supported Round Robin and Weighted Round Robin with Urgent Priority Class Arbitration

Supported Commands

List basic device information.

ADMIN COMMAND OPCODE COMMAND NAME
0x0 Delete I/O Submission Queue
0x1 Create I/O Submission Queue
0x2 Get Log Page
0x4 Delete I/O Completion Queue
0x5 Create I/O Completion Queue
0x6 Identify
0x8 Abort
0x9 Set Features
0xa Get Features
0xc Asynchronous Event Request
0x10 Firmware Commit
0x11 Firmware Image Download
0x14 Device Self-test
0x80 Format NVM
0x81 Security Send
0x82 Security Receive

List basic device information.

IO COMMAND OPCODE COMMAND NAME
0x0 Flush
0x1 Write
0x2 Read
0x4 Write Uncorrectable
0x5 Compare
0x8 Write Zeroes
0x9 Dataset Management

Thermal

SSD is becoming faster, and then hotter. Fundementally, hot is bad to the data in NAND media, and so it is necessary to control and monitor temperature.

ITEM DATA
Number of Power States 5
Power State #0 7.02 W
Power State #1 5.10 W
Power State #2 3.50 W
Power State #3 0.08 W, non operational
Power State #4 0.01 W, non operational
Thermal Management Temperature 1 (°C) -273
Thermal Management Temperature 2 (°C) -273

Health

SMART data before tests.

HEALTH ITEM DATA
Composite Temperature (°C) 51
Available Spare (%) 100
Percentage Used (%) 1
Data Units Read (LBA) 39261748000
Data Units Write (LBA) 26805165000
Host Read Commands 809550419
Host Write Commands 694796075
Controller Busy Time (minutes) 456
Power On Hours (hours) 68
Power Cycles 29
Unsafe Shutdowns 10
Media and Data Integrity Errors 0

Function

Performance

Reliability